Sub-Zero Repair Redmond · WA (425) 905-2822

532 Model · 500 Series

Sub-Zero 532 Side-by-Side

The Sub-Zero 532 is the wide 500 Series side-by-side, made for a 47 1/2 inch opening: freezer on the left, refrigerator on the right, a pull-out ice drawer, and lit dials where later units have a display. It stores no codes, so faults are found by temperature and test. Sub-Zero Repair Redmond, (425) 905-2822.

Identify it

  • Two doors side by side in a 47 1/2 inch opening, the narrower door on the left for the freezer.
  • Lit dials numbered 1 to 10 inside the cabinet and no display on the doors or the grille.
  • A pull-out ice drawer in the freezer, with the ice maker switch on the front of the freezer control panel.
  • 532 on the plate inside the freezer door, near the top hinge.
Rough opening
47 1/2 in. wide, 83 3/4 in. high
Door panels
17 15/16 and 27 11/16 in. wide, 67 11/16 in. tall
Door clearance
29 1/4 in. at 90°
Door swing
130°, optional stop kit for about 90°
Minimum height
82 7/8 in. with levelers in
Tag
Inside the freezer door, top hinge
532 at a glance — Sub-Zero Repair Redmond, (425) 905-2822

Reading the two dials

The refrigerator dial is on the back wall near the top right. The freezer dial is on the panel just above the ice drawer: pull the drawer out and it is on the left side of that panel. Both run from 1, the warmest, to 10, the coldest, and should read where they were left before anything else is blamed.

Faults on a 532, found without codes

One side warm, the other fine. The 532 runs a compressor for each side, so a warm refrigerator next to a hard-frozen freezer is traced on the refrigerator side alone, and the other way round.

No ice. The ice maker has its own switch on the freezer control panel, and it is the first thing checked, followed by the water shut-off feeding the unit. Only then is the fill valve or the ice maker itself tested.

Freezer frosting. The freezer defrosts on a timer. Frost that keeps building on the back wall points at the timer, the heater or the drain, which all sit inside the cabinet.

Doors drifting open. Both doors have spring-loaded closers, and the top hinges adjust with Allen screws. A door that no longer pulls itself shut is usually a closer or hinge setting, not a gasket.

Warm everywhere. The condenser and the fan that cools the compressor area are behind the top grille, and a blocked coil or a stalled fan takes both sides with it.

For the cabinetmaker

The doors open to 130 degrees. Where an island or a wall return sits close, Sub-Zero offered a stop kit that holds them near 90. Two units installed side by side need a filler strip between them, added to the opening width.

Condenser fan motor fitted at the open lower back of a refrigerator beside the compressor, the old fan on the floor

Asked on the phone

Why did the lights go out after a door stood open?
Sub-Zero built the 532 so its lights can switch off when a door stands open for a long time, which protects parts from heat. Close the doors for fifteen to thirty minutes and the light switch resets. If it stays dark, call Sub-Zero Repair Redmond, (425) 905-2822.

A 532 that needs a technician?

Sub-Zero Repair Redmond · $89 service call, deducted once the repair goes ahead · on site 0800 to 2000 hrs, all seven days

Checked by
Dean Halvorsen
Bench
sealed systems and airflow
Trade
19 yrs
Card
EPA 608 certified
Revised
Overhead view of an open machine compartment with bagged relays, a multimeter and screwdrivers on the carpet beside it

Next step

Series, readout,
then a price

Give us the model off the tag and whatever the display is showing. When the fix is a clean condenser or a reset you can do yourself, you will hear that on the phone. When it needs a technician, the visit is $89 and it comes off the repair bill; the price for the work is in writing before anything is opened.

Sub-Zero Repair Redmond · on site 0800 to 2000 hrs, all seven days · calls taken 24/7