EC 24: Defrost Under-Heat

EC 24 means a later 600 Series freezer defrost ended with the coil still too cold. Frost that is not fully cleared builds up from one defrost to the next. Sub-Zero Repair Redmond checks the defrost heater and how the heater and evaporator sensor are mounted; call (425) 905-2822.

EC 24 at a glance — Sub-Zero Repair Redmond, (425) 905-2822
Means Defrost under-heat: the heater did not bring the freezer coil up to temperature during defrost.
Check first
  • Frost or ice building up inside the freezer compartment.
  • Whether EC 40 is stored as well, since a frosted coil can keep the freezer compressor running.
Needs a technician
  • Defrost heater resistance measured, and the heater replaced if the reading is wrong.
  • Freezer evaporator sensor and heater checked for correct mounting on the coil, and remounted if needed.

How it differs from EC 20

Both codes say the defrost did not warm the coil enough. EC 20 adds that the control also heard nothing back from the heater circuit when defrost began. EC 24 carries no such complaint, so the search stays on two things: the heater itself, and where the heater and the evaporator sensor sit on the coil.

Two checks, in order

Sub-Zero’s list is short. The technician reads the heater’s resistance and replaces a heater that fails. Then the heater and sensor are checked for position, because a shifted sensor or heater no longer reads or warms the part of the coil it was placed on.

Leave the frost where it is

The coil sits behind a panel inside the freezer. Prying or chipping ice off it risks puncturing refrigerant tubing, which turns a heater repair into a sealed-system one.

Evaporator fan and air duct exposed behind the opened rear panel of an empty freezer compartment

EC 24 on your display?

Sub-Zero Repair Redmond · $89 service call, deducted once the repair goes ahead · on site 0800 to 2000 hrs, all seven days

Checked by
Dean Halvorsen
Bench
sealed systems and airflow
Trade
19 yrs
Card
EPA 608 certified
Revised
Overhead view of an open machine compartment with bagged relays, a multimeter and screwdrivers on the carpet beside it

Next step

Series, readout,
then a price

Give us the model off the tag and whatever the display is showing. When the fix is a clean condenser or a reset you can do yourself, you will hear that on the phone. When it needs a technician, the visit is $89 and it comes off the repair bill; the price for the work is in writing before anything is opened.

Sub-Zero Repair Redmond · on site 0800 to 2000 hrs, all seven days · calls taken 24/7